Parameter list
PNU
Description
11.52 Binector/connector converter for serial interfaces
U116
Source for binector/connector converter for GSST1
(2116)
Binectors which must be converted to connector K2020
*
st
i001:
1
binector (bit 0)
nd
i002:
2
binector (bit 1)
...
th
i016:
16
binector (bit 15)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U117
Source for binector/connector converter for GSST2
(2117)
Binectors which must be converted to connector K6020
*
st
i001:
1
binector (bit 0)
nd
i002:
2
binector (bit 1)
...
th
i016:
16
binector (bit 15)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U118
Source for binector/connector converter for GSST3
(2115)
Binectors which must be converted to connector K9020
*
st
i001:
1
binector (bit 0)
nd
i002:
2
binector (bit 1)
...
th
i016:
16
binector (bit 15)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U119
Parameters for the Trace function of SIMOVIS
(2119)
This parameter is a setting for the exchange of process data between
*
SIMOVIS and the SIMOREG converter. It must not be changed!
11.53 Mathematical functions
Parameters apply only if optional S00 technology software is installed
Adder / subtractor
The 3 operands of a function block are selected by 3 indices each of a parameter.
U120 to U131:
The connectors selected via indices i001 and i002 are added, the connector selected via index i003 is subtracted.
U120 to U122 [SW 1.8 and later]:
The connectors selected via indices i004 and i005 are added, the connector selected via index i006 is subtracted.
The result is limited to -200.00 to +199.99% and applied to the connector stated.
U120
Operands for 1st adder / subtractor (result = K9120)
(2120)
Operands for 13th adder / subtractor (result = K9132)
*
(SW 1.8 and later)
S00
0 = Connector K0000
1 = Connector K0001
etc.
11-88
Value range
[Unit]
Steps
All binector numbers
[SW1.4 and later]
1
[SW1.4 and later]
All binector numbers
1
All binector numbers
[SW1.4 and later]
1
[SW1.4 and later]
All connector
FB 20
numbers
FB 32
1
SIMOREG DC Master
02.00
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
[SW 1.4 and later]
Ind: 16
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 16
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 16
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind:
P052 = 3
3
P051 = 40
[up to
off-line
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2