Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 384

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Faults / Alarms
Fault
No.
Cause as a function of fault value
(r047.001, r949.001 or r949.009 with acknowledged error)
Fault value:
1
Connection to EEPROM is faulty
Possible fault causes
A7001 electronics board is defective
A7009 backplane wiring assembly is defective
Plug-in connection X109 is defective
2
Parameter value is outside permissible value range
Possible fault causes
"Restore to default value" has never been executed
with this software (e.g. after software replacement)
A7009 backplane wiring assembly is defective
Possible remedy:
Acknowledge fault, execute "Restore to default value"
and start up the drive again
3
Parameter value cannot be stored on EEPROM
Possible fault causes
A7001 electronics board is defective
A7009 backplane wiring assembly is defective
Plug-in connection X109 is defective
11
Checksum of non-volatile data (part 1)
is not correct
12
Checksum of non-volatile data (part 2)
is not correct
13
Checksum of non-volatile data (part 3)
is not correct
20
Checksum of configuring table of parameter values is not
correct
Possible fault causes
Defective EEPROM
"Restore to default value" has never been executed
with this software (e.g. after software replacement)
Possible remedy:
Acknowledge fault, execute "Restore to default value"
and start up the drive again! Check interference
suppression measures and improve if necessary.
F063
Errors in compensation data of analog inputs and outputs
(active in all operating states)
This function monitors whether the factory-set compensation data for the analog inputs and outputs are plausible
Possible fault cause:
Defective A7001 or A7006 electronics board
Fault value:
11
Incorrect number of words in compensation values
for analog inputs and outputs of A7001
12
Checksum error in compensation values for
analog inputs and outputs of A7001
13
Incorrect value among compensation values for
analog inputs and outputs of A7001
23
Incorrect value among compensation values for
analog inputs and outputs of A7006
10-20
Description
Further information (r047.002 to r047.016)
r047 Index 002 to 016:
i002 Number of faulty parameter
i003 Index of faulty parameter
i004 Faulty parameter value
i002 Address of fault memory location
i003 Faulty value in EEPROM
i004 Correct parameter value
i002 Calculate checksum
i003 Checksum found in EEPROM
r047 Index 002 to 016:
i002 Incorrect number of words
i002 Calculated checksum
i003 Errored checksum
i002 Incorrect value
i002 Incorrect value
SIMOREG DC Master
02.00
SIEMENS AG
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents