Mounting; Mounting The Converter; Mounting Conditions; Dimension Drawings And Drill Dimensions - Siemens SINAMICS S200 Compact Operating Instructions

Hide thumbs Also See for SINAMICS S200:
Table of Contents

Advertisement

3

Mounting

3.1

Mounting the converter

3.1.1

Mounting conditions

To ensure a reliable, continuous, and trouble-free converter operation, observe the following mounting conditions:
The converter is designed for installation in a control cabinet.
The converter is certified for use in environments with degree of pollution 2 without condensation, that is, in
environments where no conductive pollution/dirt occurs. Condensation is not permissible.
The converter fulfills degree of protection IP20 according to IEC 60529.
The converter supports vertical mounting only. Mount the converter vertically with the operator panel facing upwards.
Use a conductive steel sheet no thinner than 2 mm as the mounting plate.
3.1.2

Dimension drawings and drill dimensions

All dimensions are specified in millimeters.
Voltage
Frame size
1 AC/3 AC 200 V
FSA
FSB
FSC
3 AC 400 V
FSA
FSB
FSC
FSD
6
Width
Height
40 mm
170 mm
40 mm
170 mm
60 mm
170 mm
50 mm
180 mm
60 mm
180 mm
70 mm
180 mm
95 mm
260 mm
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Depth
Fixing
135 mm
2 x M4 / 2.5 Nm
170 mm
195 mm
200 mm
2 x M4 / 2.5 Nm
200 mm
200 mm
230 mm
4 x M4 / 2.5 Nm
A5E52388930A AA, 07/2023