Parameter list
PNU
Description
Speed controller: Filtering of setpoint and actual value, band-stop filters
P625
Source for speed controller setpoint
*
Selection of connector to be injected as the input signal for speed setpoint
FDS
filtering
0 = connector K0000
1 = connector K0001
etc.
P626
Source for actual speed controller value
*
Selection of connector to be injected as the input signal for actual speed
FDS
value filtering
0 = connector K0000
1 = connector K0001
etc.
P627
Source for input of D element
*
Selection of connector to be injected as the input signal for the D element
0 = connector K0000
1 = connector K0001
etc.
P628
Source for input of band-stop filter 1
*
Selection of connector to be injected as the input signal for band-stop filter
1
0 = connector K0000
1 = connector K0001
etc.
P629
Source for band-stop filter 2
*
Selection of connector to be injected as the input signal for band-stop filter
2
0 = connector K0000
1 = connector K0001
etc.
Speed controller droop
P630
Source for influencing quantity for speed droop
*
Selection of connector to be injected as the influencing quantity
0 = connector K0000
1 = connector K0001
etc.
Setting the speed controller I component
Function: When the binector selected in P695 switches state from log. "0" to log. "1", the I component of the speed controller is set to
the value of the connector selected in P631.
With this function it is possible, for example, to use the same signal (binector) to control controller enabling commands and
setting of the I component.
P631
Source for setting value for speed controller integrator
*
Selection of connector to be injected as the setting value for the I
component
0 = connector K0000
1 = connector K0001
etc.
11-54
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 4
numbers
FS=170
1
Type: L2
All connector
Ind: 4
numbers
FS=167
1
Type: L2
All connector
Ind: None
numbers
FS=178
1
Type: L2
All connector
Ind: None
numbers
FS=179
1
Type: L2
All connector
Ind: None
numbers
FS=177
1
Type: L2
All connector
Ind: None
numbers
FS=162
1
Type: L2
All connector
Ind: None
numbers
FS=0
1
Type: L2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
02.00
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
6RX1700-0AD76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents