Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 439

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

02.00
PNU
Description
P524
Friction at 40% speed
Setting as % of converter rated DC current or rated torque
FDS
P525
Friction at 50% speed
Setting as % of converter rated DC current or rated torque
FDS
P526
Friction at 60% speed
Setting as % of converter rated DC current or rated torque
FDS
P527
Friction at 70% speed
Setting as % of converter rated DC current or rated torque
FDS
P528
Friction at 80% speed
Setting as % of converter rated DC current or rated torque
FDS
P529
Friction at 90% speed
Setting as % of converter rated DC current or rated torque
FDS
P530
Friction at 100% speed and higher
Setting as % of converter rated DC current or rated torque
FDS
11.28 Compensation of moment of inertia (dv/dt injection)
(see also Section 8, Sheet G153)
P540
Acceleration time
The acceleration time is the time that would be needed to accelerate the
FDS
drive from 0% to 100% of maximum speed (with no friction) at 100%
converter rated DC current (armature) and 100% rated motor field current
(i.e. 100% flux). It is a measure of the moment of inertia on the motor shaft.
This parameter is set automatically during the optimization run for friction
and moment of inertia compensation (P051=28).
P541
P gain of acceleration
Proportional gain for "SAD-dependent acceleration" function (see also
FDS
parameter P543)
P542
Time difference for dy/dt of ramp-function generator
Ramp-function generator:
FDS
Setting of dt for the output of dy/dt at a connector, i.e. at K0191, the change
in the output quantity of the ramp-function generator (K0190) is output
within the period set in P542
Example: The ramp-function generator is currently ramping up with a ramp-
up time of P311=5s, i.e. a ramp-up operation from y=0% to
y=100% takes 5s.
- A time difference dt of P542=2s is set.
- ⇒ A dy/dt of 40% appears at connector K0191 since the dy
within
the set dt of 2 s equals (2s/5s)*100%..
P543
Threshold for SAD-dependent acceleration
With respect to the SAD-dependent acceleration function, only the
FDS
component of the speed controller setpoint/actual value difference which
has an absolute value in excess of the threshold set in this parameter is
switched through (see also parameter P541).
199.99%
negative
threshold
-200.00%
(-P543)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Output (value to be multiplied by P541)
Input (setp./act. val. diff.)
positive
199.99%
threshold
(P543)
-200.00%
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.0 to 100.0
Ind: 4
[%]
FS=0.0
0.1%
Type: O2
0.00 to 650.00
Ind: 4
[s]
FS=0.00
0.01s
Type: O2
0.00 to 650.00
Ind: 4
0.01
FS=0.00
Type: O2
0.01 to 300.00
Ind: 4
[s]
FS=0.01
0.01s
Type: O2
0.00 to 100.00
Ind: 4
[%]
FS=0.00
0.01% of maximum
Type: O2
speed
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
11-47