Siemens SIMOREG DC Master 6RA7028-6DS22 Operating Instructions Manual page 168

Microprocessor-based converters from 6kw to 1900kw for variable-speed dc drives 6ra70 series
Table of Contents

Advertisement

Start-Up
Index
015/047 Every bit marks a process data no. (1-10)
in the receive message to which a 32-bit
value is assigned
016/048 -
017/049 -
018/050 -
019/051 -
020/052 -
021/053 -
022/054 -
023/055 -
024/056 -
025/057 Date of creation: Day, month
026/058 Date of creation: Year
027/059 Software version
028/060 Software version
029/061 Software version
030/062 -
031/063 -
032/064 -
7-26
Meaning for CB1
Meaning for CBP/CBP2
H byte: Mirroring of "DWord specifier act"
L byte: DPV1:DS_Write, pos. ack. counter
H byte: Reserved
L byte: DPV1:DS_Write, neg. ack. counter
H byte: Reserved
L byte: DPV1:DS_Read, pos. ack. counter
H byte: Reserved
L byte: DPV1:DS_Read, neg. ack. counter
H byte: Reserved
L byte: DP/T:GET DB99 pos. ack. counter
H byte: DP/T:PUT DB99 pos. ack. counter
L byte: DP/T:GET DB100 ps. ack. counter
H byte: DP/T:PUT DB100 ps. ack. counter
L byte: DP/T:GET DB101 ps. ack. counter
H byte: DP/T:PUT DB101 ps. ack. counter
L byte: DP/T service neg. acknow. counter
H byte: DP/T:Application association pos.
acknow. counter
Reserved
Date of creation: Day, month
Date of creation: Year
Software version (Vx.yz, display x)
Software version (Vx.yz, display yz)
Software version: Flash-EPROM checks.
Reserved
Reserved
Reserved