Service settings via software (OP3000)

4
This chapter describes service settings:
• Presettings for sewing programs and functions
• Basic machine settings
• Advanced machine settings
• Test functions for individual elements in the machine
• Calibration functions
• Resetting the machine
Changes to stitch length, thread tension, curve support, etc. and the
calling up and compiling of sewing programs is described in the
 Operating Instructions.

4.1 Calling up the Technician level

All settings in the service menu must be carried out in the Technician level.
Important
For safety reasons, the pedal at the technician level is not active! While
you can test the pedal input in the submenu Multitest, the sewing mo-
tor is not activated by the pedal.
To select the Technician level:
1. Press and hold the buttonsP and S at the same time.
 The input mask for the code appears on the display:
Fig. 45: Calling up the Technician level, input mask
2. Enter code 25483 using the numeric keys.
 Each time a number is entered, the input cursor will
Service Instructions 650-10 - 01.0 - 08/2016
Service settings via software (OP3000)
080
0 ****
automatically jump to the next position. The numbers are not shown
for reasons of security. A 0 appears at the relevant entry point; aster-
isks are in the other positions.
/
Use
to move from one entry point to another.
10 2
1
55