Messages Of The Software/Control Panel - Dürkopp Adler 513 Operating Instructions Manual

Table of Contents

Advertisement

Troubleshooting
Error
Description
E-068
Stepper motor
error loop DSP2
nd
2
path (X21)
position error
E-069
Stepper motor
error loop DSP2
nd
2
path (X21)
overspeed
E-070
Stepper motor
card error 90V
power supply
Error
Description
M-300
Memory
abnormal
Operating Instructions 513/533 - 01.0 - 09/2023
Possible cause
The detected encoder response
position does not correspond to
the position specified in the
order.
The system issues this warning
if detecting an abnormal speed
via the encoder response
signal.
The stepper motor card is
overloaded with 90V.
9.3

Messages of the software/control panel

Possible cause
An error has occurred in
the data that was defined using
the control panel.
Troubleshooting
• Switch the stepper motor to
open loop mode and let it run.
• If the motor is able to operate
normally, it is OK.
• If the motor is unable to
operate normally, the user
should check the drive
component on the stepper
motor PCB and the motor itself.
• After completing the
procedures above, the user
should check the encoder.
• Make sure the connection
and the condition of the
encoder cable are OK.
• Make sure the signal
response on the stepper
switch panel board and the
encoder itself are OK.
The method used for checking
is the same as for position error
E-068.
• Switch off the power supply
unit and switch it back on after
waiting for a while.
Troubleshooting
• Internal error: The user needs
to update the software of the
control panel.
113

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

533

Table of Contents