Dismounting thread tensioner
Fig. 35: Dismount electrical thread tensioner
(1) - Thread tensioner
(2) - Access hole in the
To dismount the electric thread tensioner:
1. Loosen the setscrew through the access hole (2).
2. Pull out the thread tensioner (1) approx. 1 cm and turn counterclock-
3. Pull the thread tensioner (1) forward as far as the length of the cable
You can now adjust the following settings:
• Check the lifting gear ( p. 42)
• Change the thread tensioning spring ( p. 48)
• Set the spring tension ( p. 50)
Only when installing a new thread tensioner:
4. Remove the cable shoe (4) from the transparent plug (3) on the rear
5. Carefully remove the thread tensioner (1) forwards together with the
46
housing face side
wise so that the cables point downwards and can be pulled out through
the cable cutout.
Important
Pull out the thread tensioner carefully so as not to damage the cable!
allows.
of the stepper motor.
cables.
Individual settings
(3) - Plugs
(4) - Cable shoe