Service settings via software (OP3000)
Fig. 66: Thread Calib., Set calibration position 3 (2)
(1) - Adjusting nut
(2) - Tension disks
5. Completely loosen the setscrew (3) in the middle of the thread
6. Screw in the adjusting nut (1) as far as possible without pressing the
7. Slowly loosen the adjusting nut (1) again while observing the display
8. At the point at which the measurement device displays a value of 300 g:
9. Press the OK key.
Set calibration position 2 as follows:
1. Use
2. Press the OK key.
3. Use
4. Press the OK key.
Set calibration position 1 as follows:
1. Use
2. Press the OK key.
3. Use
4. Press the OK key.
Service Instructions 650-10 - 01.0 - 08/2016
(3) - Setscrew
tensioner.
tension disks (2) against each other.
on the thread tension measurement device.
Tighten the setscrew (3) without changing the position of the adjusting
nut (1).
/
to select calibration position 2.
/
to change the thread tension until the measurement device
displays a value of 150 g.
/
to select calibration position 1.
/
to change the thread tension until the measurement device
displays a value of 5 g.