For a controlled shutdown, select Momentary Press.
For an emergency shutdown, select Press and Hold.
Before proceeding, verify that the Server Blade is in standby mode by observing that the system power LED
is amber.

Remove the Server Blade

1. Identify the proper Server Blade.
2. Power down the Server Blade .
3. Remove the Server Blade.
4. Place the Server Blade on a flat, level work surface.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the Server Blade before beginning any
installation procedure. Improper grounding can cause ESD.

Install the server blade

CAUTION:
To prevent improper cooling and thermal damage, do not operate the server blade enclosure unless all
bays are populated with either a component or a blank.
CAUTION:
Failure to install the divider in a quadrant when installing half-height blades can result in damage to the
connectors on the server blades.
For the best possible BladeSystem and Virtual Connect experience, and to prevent a future reboot, Hewlett
Packard Enterprise requires updating the Onboard Administrator and Virtual Connect to the correct version
before installing a ProLiant Gen10 Server Blade. The version information is located on the tag on the front of
the Server Blade.
Remove the Server Blade
23