System battery replacement

If the Server Blade no longer automatically displays the correct date and time, then replace the battery that
provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING:
The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline
battery pack. A risk of fire and burns exists if the battery pack is not properly handled. To reduce the risk
of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
Procedure
1. Power down the Server Blade .
2. Remove the Server Blade .
3. Place the Server Blade on a flat, level work surface.
4. Remove the access panel.
5. Identify the battery location.
6. Remove the left DIMM baffle.
7. Remove the battery.
IMPORTANT:
Replacing the system board battery resets the system ROM to its default configuration. After
replacing the battery, reconfigure the system through UEFI System Utilities.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.