P781 Data message

Applicable only to ports programmed for printer communication (P770).
Note:
Sets the data message to be delivered via the selected port, ports 1 to 3 (P781-01 to -03).
All messages and printouts include time and date.
Entry:
f
0
= no message
1 = rate
1)
2 = total
3 = load
4 = speed
1)
5 = rate, total
, load and speed
6 = rate and total
2)
7 = batching
8 = rate and speed
9 = quick start parameters (P001 – P017)
10 = all parameters

P799 Communications Control

Assigns programming control either locally through the keypad or Dolphin Plus (P770 = 1),
or remotely through Modbus protocol (P770 = 2 or 3) or SmartLinx®
Entry:
0 = local
1 = remote
WARNING: When a SmartLinx® card is installed and P799 = 1,
the parameters that the SmarlLinx® card is writing to the BW500
and BW500/L will be continuously updated. Therefore, if you
connect a SmartLinx® card to the BW500 and BW500/L, set P799
= 1 and not write anything to the SmarLinx® card, your setpoints
will be 0.
1)
Totalizer 1 and/or 2 as set by P647, Totalizer Display.
2)
Not available with BW500/L