Appendix; Io-Link Process Data Structure - Siemens SITRANS F FM100 Operating Instructions Manual

Electromagnetic flowmeters
Table of Contents

Advertisement

SITRANS FM100

17. Appendix

17.1 IO-Link process data structure

Process data length: 9 bytes
Byte
Data
no.
0 - 2 Flow
3 - 6 Volume
7 - 8 Temperature
reserved
reserved
Status OUT1
Status OUT2
Flow (24 Bit, IntegerT)
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
Byte 0
Volume (32 Bit, FloatT)
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
Byte 3
Temperature (12 Bit, IntegerT)
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
Byte 7
page 54
Bit count
Format
24 Bit
IntegerT 1/1000 +/-8388,608
32 Bit
FloatT
12 Bit
IntegerT 1/10
1 Bit
BooleanT
1 Bit
BooleanT
1 Bit
BooleanT
1 Bit
BooleanT
Byte 1
Byte 4
Byte 8
Factor
Range
+/-1,4*10
-45
... +/-3,4*10
+/-204,8
0 1 2 3 4 5 6 7
Byte 2
0 1 2 3 4 5 6 7
Byte 5
Value
L/min
+38
L
°C
0 1 2 3 4 5 6 7
Byte 6
A5E48762204-AA

Advertisement

Table of Contents
loading

Table of Contents