Scale – LVDT
belt scale with
LVDT
maximum cable run LVDT to Conditioner 300 m (1000 ft)
Siemens Milltronics
BW500 and BW500/L
Where separation between the BW500 and BW500/L and LVDT conditioner exceeds 150
m (500 ft):
1.
remove jumpers from BW500 and BW500/L terminal 11/12 and 13/14
2.
run additional conductors from:
BW500 terminal 12 to integrator terminal block '+EXC'
BW500 terminal 13 to integrator terminal block '-EXC'
For further connection information on specific LVDTs consult Siemens.
7ML19985DK05Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
Siemens Milltronics LVDT Conditioner
Page 19