relay output
• BW500
• BW500/L
Communications
• two RS-232 ports
• one RS-485 port
• SmartLinx® compatible (see
Cable
one load cell
• non-sensing
• sensing
1)
two/four/six
load cells
• non-sensing
• sensing
speed sensor
auto zero
remote total
Options
Speed Sensor
Dolphin Plus
SmartLinx®Modules
1)
For four or six load cell scales, run two separate cables of the two load cell configuration. Four/
six load cells not available with BW500/L.
7ML19985DK05Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
5 alarm/control relays, 1 form 'A' SPST relay contact per
relay, rated 5 A at 250 V AC, non-inductive
2 alarm relays
Options
below)
Belden 8404, 4 wire shielded, 20 AWG or equivalent, 150 m
(500 ft.) max.
Belden 9260, 6 wire shielded, 20 AWG or equivalent,
300 m (1000 ft.) max.
Belden 9260, 6 wire shielded, 20 AWG or equivalent,
150 m (500 ft.) max.
Belden 8418, 8 wire shielded, 20 AWG or equivalent,
300 m (1000 ft.) max.
Belden 8770, 3 wire shielded, 18 AWG or equivalent,
300m (1000 ft.)
Belden 8760, 1 pair, twisted/shielded, 18 AWG, 300 m
(1000 ft.) max.
Belden 8760, 1 pair, twisted/shielded, 18 AWG, 300 m
(1000 ft.) max.
Siemens MD-36/36A/256 or 2000A, RBSS, TASS,
WS100, or WS300, or compatible
Siemens Windows®based software interface (refer
to associated product documentation)
protocol specific modules for interface with popular
industrial communications systems (refer to
associated product documentation)