P416-01 External Setpoint
Setpoint
P418-01 Remote Setpoint Ratio
Enter % of Master Output
P250-01 mA Input Range
Select 1- 0 to 20, 2-4 to 20
P255-01 mA Input Function
Select 0, 1-PID SP, 2-PID PV
The PID setpoint can be modified while in RUN mode using the up/down
Note:
arrow keys.
Page 82
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS 7ML19985DK05
current setpoint value in engineering units,
E
obtained from the mA input
0
increase or decrease to scale input set-
V
point, if desired.
100.000
select the appropriate range for the mA
E
input signal
2
assign either:
E
1: PID setpoint, or
0
2: process variable as the function of the
mA input