Recalibration

Belt Speed Compensation

To achieve optimum accuracy in the rate computation, the belt speed displayed must
equal that of the actual belt speed. As the speeds are likely to differ, a belt speed
compensation should be performed.
Run the conveyor with the belt empty.
View the belt speed.
Access P018
P018 Speed Adjust
Enter New Speed
Stop the conveyor and measure a length of the belt; marking the forward end (start time)
and the back end (stop time). Use the belt scale as the stationary reference.
Run the belt and measure the time for the belt length to pass over the scale.
speed =
Start Up
Refer to the
changing values.
Press
P018 Speed Adjust
Enter New Speed
Press
P015 Speed Constant
Pulses/m
if
P014 Design Speed
Enter Speed
The displayed speed (used in the rate computation) now equals the actual speed.
7ML19985DK05Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
belt length
m/s or ft/min.
time
section on page 28 for instructions on parameter selection and
97.5169
0.63 m/s
e.g. current speed of 0.6 m/s
V
0.60
e.g. current speed of 0.6 m/s
E
e.g. enter correct speed of 0.63 m/s
0.60
speed sensor constant, adjust for P015
V
for constant speed (jumper), adjusts P014
V