Factoring

For optimum accuracy in the factoring results, a routine zero calibration is
Note:
recommended.
To calculate the value of a new or unknown test weight to the current span, the factoring
procedure is used.
With the belt empty, the test weight in place, and the conveyor running:
Access P359 in VIEW mode
P359 Factoring
Select 1-Weight, 2-Chain
Press
Factoring Weight
Place weight and press ENTER.
Press
Factoring Weight
Factoring in progress
Factoring Weight
Press ENTER to accept value
Press
P017 Test Load Weight:
Enter Test Load
Factoring is complete. Remove test weight and return to RUN mode if desired.
If multispan function is used, the test load value is stored for the current
Note:
multispan only.
Page 58
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS 7ML19985DK05
V
e.g. factor the test weight
the load reported while factoring is in
##.## kg/m
progress
e.g. the new factor, if accepted
45.25
V
e.g. the current test load value
45.25