Siemens Milltronics BW500 Operating Lnstructions page 108

Hide thumbs Also See for Milltronics BW500:
Table of Contents

Advertisement

Command Controls (41,022)
The command control word is used to control the unit. Each bit gives access to a
command or state as if the operator was using the keypad.
Bits initiating a command (7-12) must change state to cause the command the begin. For
example, to reset totalizer 1, Bit 9 must be set to 0, then changed to 1. It can stay set or
clear for any period:
Bit #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
a)
Not available with BW500/L.
WARNING: Before the BW500BW500 and BW500/L can be
commanded remotely, parameter P799 must be set for remote
control.
Page 102
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS 7ML19985DK05
Description
a)
PID 1 Mode
a)
PID 1 Freeze
PID 1 Setpoint
a)
Source
a)
PID 2 Mode
a)
PID 2 Freeze
PID 2 Setpoint
a)
Source
Zero
Span
Reset Totalizer 1
Reset Totalizer 2
Reset Batch Total-
a)
izer
Print
-
-
-
-
Bit Clear
Bit Set (1)
Manual
No
Local
Manual
No
Local
No change
No change
No change
No change
No change
-
-
-
-
-
Auto
Yes
Remote
Auto
Yes
Remote
Start
Start
Reset
Reset
Reset
Print
-
-
-
-