Interconnection

Note:
Wiring may be run via common conduit. However, these may not be run in the
same conduit as high voltage contact or power wiring.
Ground shield at one point only.
Insulate at junctions to prevent inadvertent grounding.

System Diagram

Typical system capability. Not all components or their maximum quantity may
Note:
be required
.
Page 14
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS 7ML19985DK05
Milltronics
BW500 and BW500/
L
optional SmartLinx®
belt scale, see
Specifications
speed sensor,
optional, see
Specifications
mA output to
customer device
mA output to
customer device
(optional I/O board
required)
mA input from
customer device
(optional I/O board
required)
relay output, to
customer device
(2 for BW500/L)
auxiliary inputs
customer remote
totalizer
optional fieldbus
connection
(SmartLinx card
required)
communication
ports can be
configured for
Siemens
Milltronics Dolphin
Plus, print data, or
Modbus ASCII or
RTU protocol