Interconnection
Note:
•
Wiring may be run via common conduit. However, these may not be run in the
same conduit as high voltage contact or power wiring.
•
Ground shield at one point only.
•
Insulate at junctions to prevent inadvertent grounding.
System Diagram
Typical system capability. Not all components or their maximum quantity may
Note:
be required
.
Page 14
Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS 7ML19985DK05
Milltronics
BW500 and BW500/
L
optional SmartLinx®
belt scale, see
Specifications
speed sensor,
optional, see
Specifications
mA output to
customer device
mA output to
customer device
(optional I/O board
required)
mA input from
customer device
(optional I/O board
required)
relay output, to
customer device
(2 for BW500/L)
auxiliary inputs
customer remote
totalizer
optional fieldbus
connection
(SmartLinx card
required)
communication
ports can be
configured for
Siemens
Milltronics Dolphin
Plus, print data, or
Modbus ASCII or
RTU protocol