Press
P014 Design Speed
Enter Speed
Press
P014 Design Speed
Enter Speed
Press
P015-01 Speed Constant
Pulses/m
If the speed input is configured for constant speed, display value reads 'Jumpered'
press
to advance.
If the speed input is connected to a speed sensor, pressing enter at P015 invokes P690 for
data entry.
Press
P690-01 Speed Constant Entry
1-Calculated, 2-Sensor Data
Select: 1 - Calculated
The program returns to P015. Calculate the
value per Parameter P690.
Press
P015-01 Speed Constant
Pulses/m
Press
e.g. speed constant of 100.3 pulses
per meter
This value is calculated. For manual or automatic calculation, refer to
To program Differential Speed (P015-02), follow steps above for P015-01.
P016 Belt Length
Enter Length
7ML19985DK05Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
factory design speed
V
0.00 m/s
E
e.g.speed of 0.8 m/s
0.00 m/s
V
0.0000
E
1
Select: 2 - Sensor Data
The program advances through parameters P691
and P692 prompting entry from the sensor name-
plate. From this data, the speed constant is cal-
culated and automatically entered into P015.
E
P691-01 Step 1: Drive Pully Diameter
0.0000
P692-01 Step 2: Pulses per sensor Rev.
Enter Pulses
P015-01 Speed Constant
Pulses/m
V
factory set length
0.000 m
V
0.00 mm
V
0.00
V
0.0000
P690
on page 140.