mA I/O Board connections
Installing/replacing the back-up battery
The battery (see Specifications, page 5) should be replaced every 5 years to ensure back
up during lengthy power outages. An on board capacitor provides 20 minutes of charge to
preserve the memory while the battery is being changed.
Note:
•
Do not install the memory backup battery until the BW500 and BW500/L is
installed, as it begins operation immediately.
•
The unit is supplied with one battery (battery P/N PBD-2020035 (BR 2335) or use
equivalent 3V Lithium battery). Insert the battery into the holder as shown in the
following diagram before using the BW500 and BW500/L.
Disconnect power before installing or replacing the battery.
1)
Not available with BW500/L.
7ML19985DK05Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
1)
auxiliary supply output, isolated 24 V DC at
50 mA, short circuit protected
from customer instrumentation, isolated mA
input, 200
from customer instrumentation, isolated mA
input, 200
to customer instrumentation, isolated mA
output, 750 maximum load
to customer instrumentation, isolated mA
output, 750 maximum load
Installation Steps
1.
Open the enclosure lid.
2.
Slide the battery into the holder.
Be sure to align the + and –
terminals correctly.
3.
Close and secure enclosure lid.