Ma I/O Board Connections; Installing/Replacing The Back-Up Battery - Siemens Milltronics BW500 Operating Lnstructions

Hide thumbs Also See for Milltronics BW500:
Table of Contents

Advertisement

mA I/O Board connections

Installing/replacing the back-up battery

The battery (see Specifications, page 5) should be replaced every 5 years to ensure back
up during lengthy power outages. An on board capacitor provides 20 minutes of charge to
preserve the memory while the battery is being changed.
Note:
Do not install the memory backup battery until the BW500 and BW500/L is
installed, as it begins operation immediately.
The unit is supplied with one battery (battery P/N PBD-2020035 (BR 2335) or use
equivalent 3V Lithium battery). Insert the battery into the holder as shown in the
following diagram before using the BW500 and BW500/L.
Disconnect power before installing or replacing the battery.
1)
Not available with BW500/L.
7ML19985DK05Milltronics BW500 and BW500/L - OPERATING INSTRUCTIONS
1)
auxiliary supply output, isolated 24 V DC at
50 mA, short circuit protected
from customer instrumentation, isolated mA
input, 200
from customer instrumentation, isolated mA
input, 200
to customer instrumentation, isolated mA
output, 750 maximum load
to customer instrumentation, isolated mA
output, 750 maximum load
Installation Steps
1.
Open the enclosure lid.
2.
Slide the battery into the holder.
Be sure to align the + and –
terminals correctly.
3.
Close and secure enclosure lid.