Mitsubishi Electric R16MTCPU Programming Manual page 49

Hide thumbs Also See for R16MTCPU:
Table of Contents

Advertisement

Positioning control
Instruction
symbol
Fixed-Pitch
1 axis
FEED1
feed control
2 axis
FEED2
3 axis
FEED3
Speed
Forward
VF
control ()
rotation
Reverse
VR
rotation
Speed
Forward
VVF
control ()
rotation
Reverse
VVR
rotation
Speed/
Forward
VPF
position
rotation
switching
Reverse
VPR
control
rotation
Speed
Forward
PVF
control with
rotation
fixed
Reverse
PVR
position stop
rotation
Position follow-up
PFSTART
control
Home position return
ZERO
High speed oscillation
OSC
NOP instruction
NOP
Control description
1 Axis Fixed-Pitch Feed Control
2-axes linear interpolation fixed-pitch feed control
3-axes linear interpolation fixed-pitch feed control
Speed control () forward rotation start
Speed control () reverse rotation start
Speed control () forward rotation start
Speed control () reverse rotation start
Speed/position switching control forward rotation start
Speed/position switching control reverse rotation start
Speed control with fixed position stop forward rotation start
Speed control with fixed position stop reverse rotation start
Position follow-up control start
Home position return start
High-speed oscillation
No operation
Setting
Remark
value
03H
0CH
17H
04H
05H
70H
71H
06H
• VPSTART instruction is not supported.
• If VPF/VPR instructions are executed
by M(P).SVSTD/D(P).SVSTD
07H
instructions and VPSTART instruction
is executed by the Motion SFC
program, a minor error (error code:
19FCH) occurs.
73H
• Set a bit device of the Motion CPU to
use for fixed position stop command to
(D1). If a valid device is not set to (D1),
74H
error code (2225) is stored to the
complete status (S1+0), and control
does not start. When a number outside
the range is set, a minor error (error
code: 19FCH) occurs.
• Acceleration/deceleration time is set by
"acceleration time (b4)" of positioning
data items setting. If not set, error code
(2224) is stored to the complete status
(S1+0), and control does not start.
75H
Set a word device of the Motion CPU to
store the follow-up address to (D1). If a
valid device is not set to (D1), error code
(2225) is stored to the complete status
(S1+0), and control does not start. When
a number outside the range is set, a
minor error (error code: 19FCH) occurs.
76H
Home position return is performed based
on home position return data. Data other
than "[Da.2] Control mode" is ignored.
77H
Set the high speed oscillation setting
items (starting angle, amplitude,
frequency) to the following positioning
point data.
• Amplitude: [Da.6] Positioning address/
Travel value
• Starting angle: [Da.7] Arc address
• Frequency: [Da.8] Command speed
80H
2 MOTION DEDICATED PLC INSTRUCTION
2.2 Motion Dedicated PLC Instruction
2
47