Mitsubishi Electric R16MTCPU Programming Manual page 241

Hide thumbs Also See for R16MTCPU:
Table of Contents

Advertisement

Cam curve type
Setting
Cam curve name
value
7
Trapecloid
Two-dwelling
asymmetrical
8
Reverse trapecloid
9
Double hypotenuse
One-dwelling
10
Reverse double
hypotenuse
11
Single hypotenuse
Non-dwelling
curve
*1
: Stroke ratio
: acceleration
*1
Acceleration curve shape
P1
P2
P1
P2
P1
P2
P1
P2
P1
P2
: Range L1
: Range L2
4.16 Advanced Synchronous Control Dedicated Function
Curve applicable
Acceleration/deceleration range
range
compensation
(P1 to P2)
Range L1
0.00 to 1.00
0.0001 to 0.2499
(0.1250)
0.00 to 1.00
0.0001 to 0.2499
(0.1250)
0.00 to 1.00
0.00 to 1.00
0.00 to 1.00
4 OPERATION CONTROL PROGRAMS
Range L2
4
239