Mitsubishi Electric R16MTCPU Programming Manual page 330

Hide thumbs Also See for R16MTCPU:
Table of Contents

Advertisement

Transition conditional expressions
Classifications
Symbol
Bit device status
(None)
!
Logical operation
*
+
Comparison
==
operation
!=
APPENDICES APPENDIX
328
Appendix 1 Processing Times
Instruction
Operation expression
ON (Normally
M0
open contact)
X100
(Completion of
*1
X20
condition)
U3E1\G10000.0
U3E1\HG10000.0
OFF (Normally
!M0
closed contact)
!X100
(Completion of
*1
!X20
condition)
!U3E1\G10000.0
!U3E1\HG10000.0
Logical AND
M0*M1
X100*X101
*1
X20*X20
U3E1\G10000.0*U3E1\G10000.1
U3E1\HG10000.0*U3E1\HG10000.1
Logical OR
M0+M1
X100+X101
*1
X20+X20
U3E1\G10000.0+U3E1\G10000.1
U3E1\HG10000.0+U3E1\HG10000.1
Equal to
#0==#1
(Completion of
D800==D801
condition)
U3E1\G10000==U3E1\G10001
U3E1\HG10000==U3E1\HG10001
#0L==#2L
D800L==D802L
U3E1\G10000L==U3E1\G10002L
U3E1\HG10000L==U3E1\HG10002L
#0F==#4F
D800F==D804F
U3E1\G10000F==U3E1\G10004F
U3E1\HG10000F==U3E1\HG10004F
Not equal to
#0!=#1
(Completion of
D800!=D801
condition)
U3E1\G10000!=U3E1\G10001
U3E1\HG10000!=U3E1\HG10001
#0L!=#2L
D800L!=D802L
U3E1\G10000L!=U3E1\G10002L
U3E1\HG10000L!=U3E1\HG10002L
#0F!=#4F
D800F!=D804F
U3E1\G10000F!=U3E1\G10004F
U3E1\HG10000F!=U3E1\HG10004F
Unit [µs]
0.6
1.3
6.7
1.8
1.6
0.8
1.4
6.9
1.9
1.8
1.4
2.1
11.1
2.9
2.7
1.3
2.1
11.1
2.9
2.7
1.6
1.5
2.9
2.7
2.0
1.7
3.1
2.8
1.8
1.8
3.1
2.9
1.6
1.6
2.9
2.7
1.8
1.7
3.1
2.8
3.5
1.8
3.2
2.9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R64mtcpuMelsec iq-r seriesR32mtcpu

Table of Contents