■Description, range, setting side, data type
Setting data
Description
(n1)
(First I/O No. of the target CPU)/16
Value to specify actually is the following.
CPU No.2: 3E1H, CPU No.3: 3E2H, CPU No.4: 3E3H
*3
(S1)
Axis No. ("Jn")
R64MTCPU: J1 to J64
R32MTCPU: J1 to J32
R16MTCPU: J1 to J16
(n2)
Speed to change
*1
(D1)
Complete devices
• (D1+0): Device which make turn on for one scan at accept completion of instruction.
• (D1+1): Device which make turn on for one scan at accept abnormal completion of
instruction. ("D1+0" also turns on at the abnormal completion.)
*1
(D2)
Complete status storage device
*1 Omission possible with both of (D1) and (D2) omission.
*2 Motion CPU cannot be set as CPU No.1 in the Multiple CPU configuration.
*3 "n" shows the numerical value correspond to axis No. (n=1 to 64)
*4 The setting range of each setting unit for (n2) is shown below.
Unit
(n2) usable range
mm
-600000000 to 600000000 (10
inch
-600000000 to 600000000 (10
degree
-2147483647 to 2147483647 (10
pulse
-2147483647 to 2147483647[pulse/s]
*5 When the "speed control 10  multiplier setting for degree axis" is set to "valid", the setting range is -2147483647 to 2147483647 (10
2
[degree/min]).
Processing details
■Controls
• The speed of command generation axis specified with (S1) is changed to the speed specified with (n2) during positioning or
JOG operating.
• There is not an interlock signal on the buffer memory during speed change. When the multiple instructions are executed
toward the same axis of same Motion CPU, the speed is changed to specified value by last instruction.
• Acceleration/deceleration time at speed change can be changed by setting the acceleration/deceleration time change
parameter of the axis specified with (S1). Refer to the following for acceleration/deceleration time change parameter.
MELSEC iQ-R Motion controller Programming Manual (Advanced Synchronous Control)
Refer to the following for acceleration/deceleration time change function.
MELSEC iQ-R Motion controller Programming Manual (Positioning Control)
*2
to execute the speed change.
-2
[mm/min])
-3
[inch/min])
-3
*5
[degree/min])
Setting range
Set by
3E1H to 3E3H
User
1 to 64
User
*4
User
System
System
2 MOTION DEDICATED PLC INSTRUCTION
2.2 Motion Dedicated PLC Instruction
Data type
16-bit binary
2
Character
string
32-bit binary
Bit
Word
-
65