Setting up the machine
2.6 Measuring the workpiece zero
Note
User-specific defaults
• "Setting ring diameter"
• "Height of the reference surface in the infeed axis"
Please refer to the machine manufacturer's specifications.
2.6.5
Setting the edge
The workpiece lies parallel to the coordinate system on the work table. You measure one
reference point in one of the axes (X, Y, Z).
Precondition
You can insert any tool in the spindle for scratching when measuring the workpiece zero
manually.
- OR -
An electronic workpiece probe is inserted in the spindle and activated when measuring the
workpiece zero automatically.
84
For the entry field "Diameter setting ring" (diameter, reference piece), fixed values can be
separately entered at parameters for each probe number (calibration data set number). If
these parameters are assigned, the values saved there are displayed in the entry field
"Diameter setting ring"; however, they can no longer be changed there.
For the entry field "Height of the reference surface" fixed values can be separately
entered at parameters for each probe number (calibration data set number). If these
parameters are assigned, the values saved there are displayed in the entry field "Height
of the reference surface"; however, they can no longer be changed there.
Operating Manual, 09/2011, 6FC5398-7CP40-2BA0
Milling