Plc And Nc Variables; Displaying And Editing Plc And Nc Variables - Siemens SINUMERIK 840D sl Operating Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

21.5

PLC and NC variables

21.5.1

Displaying and editing PLC and NC variables

The "NC/PLC variables" window allows NC system variables and PLC variables to be
monitored and changed.
You receive the following list in which you can enter the desired NC/PLC variables in order to
display the actual values.
● Variable
● Comment
● Format
● Value
PLC variables
Inputs
Outputs
Bit memory
Times
Meters
Data
Formats
B
H
D
+/-D
F
A
Milling
Operating Manual, 09/2011, 6FC5398-7CP40-2BA0
Address for NC/PLC variable
Incorrect variables have a red background and are displayed with a # character in the
value column.
Any comment on the variable.
The columns can be displayed and hidden.
Specify the format in which the variable is to be displayed.
The format can be specified (e.g. floating point)
Displays the actual value of the NC/PLC variables
Input bit (Ex), input byte (EBx), input word (EWx), input double word (EDx)
Output bit (Ax), output byte (ABx), output word (AWx), output double word
(ADx)
Memory bit (Mx), memory byte (MBx), memory word (MWx), memory
double word (MDx)
Time (Tx)
Counter (Cx)
Data block (DBx): data bit (DBXx), data byte (DBBx), data word (DBWx),
data double word (DBDx)
Binary
Hexadecimal
Decimal without sign
Decimal with sign
Floating point (for double words)
ASCII character
Alarms, error messages, and system alarms
21.5 PLC and NC variables
639

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents