FUTABA 4PV Instruction Manual page 121

2.4ghz t-fhss telemetry system
Table of Contents

Advertisement

2
(Recording cycle setting)
Select the setting item "CYCL" by moving the
(JOG) button up or down, and set the data ac-
quisition interval from a minimum 0.1 second to
a maximum 60 seconds with the (+) button or (-)
button.
The maximum recordable time set by CYCL is
displayed at END TIME shown below.
3
(Count alarm ON/OFF)
Select the setting item "ALRM" by moving the
(JOG) button up or down. To sound an electron-
ic beep at each log count, set "ALRM" to ON
with the (+) button or (-) button.
"OFF" : Alarm OFF.
"ON" : Alarm ON at each log count.
When finished with setting, return to the MENU screen by
pressing the (END) button.
Log function start/stop operation
1
(Log start operation)
-Start by switch (PS2)
When the switch (PS2) set by select switch
function (p.72) is pressed, data logging starts.
-Starting by throttle trigger
Display the log setting "LOG MODE" screen
and select the "STATE" setting item by the (JOG)
button operation. Press the (JOG) button for ap-
proximately 1 second.
An electronic beeping sound is generated and the "STATE" display switches from "RST" to
blinking "RDY", and the logger enters the trigger operation wait state. When the trigger is
operated in the forward direction, data logging begins. (STATE display "STA") When the end
time arrives, an electronic beep sounds and data logging stops. Return to the MENU screen
during data logging by pressing the (END) button.
2
(Log forced end)
To abort logging, press the switch (PS2), the same as starting, or display the log setting
"LOG MODE" screen and select the "STATE" setting item moving the (JOG) button opera-
tion. Then press the (JOG) button for approximately 1 second. An electronic beeping sound
is generated and logging is stopped.
4PV-Eng-08-3-Function-P93-128.indd
121
Telemetry "TELEMETRY"
Log recording time
20s ( s e c o n d s ) ~3h 20m (3
hours 20 minutes)
The maximum recordable time
set by CYCL is displayed auto-
matically.
Log recording cycle
0.1~60s(
sec
)
0.1~10s(
)0.1s step
sec
10s~60s(sec)1s step
Initial value: 1.0
sec
Adjust button
- Adjust with the (+) and (-) but-
tons.
- Return to the initial value by
pressing the (+) and (-) buttons
simultaneously (approx. 1 sec).
Alarm ON/OFF
ON, OFF
- Select with the (+) or (-) but-
tons.
Status display
RDY :Throttle trigger operation wait
STA :Logger running
STP : Logger stopped
2016/08/05
121
10:13:22