Wum (Wireless Universal Module) - Abus SECVEST Installer Manual

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Configuration

WUM (Wireless Universal Module)

Name/function
Number
Name
Adding a wireless universal module.
Note
Ensure that reserved outputs and zones are
assigned to each WAM.
See the table of reserved WAM outputs/zones
below.
Wireless
Reserved
universal
outputs
module
WAM 1
229–232
WAM 2
225–228
221 – 224
WAM 3
WAM 4
217–220
WAM 5
213–216
WAM 6
209–212
WAM 7
205–208
WAM 8
201–204
56
Explanation
The number comprises the component type (WAM) and a consecutive number.
Unique name of the wireless universal module
Reserved
zones
248
247
246
245
244
243
242
241
Note
Configure the universal module as describe in the
WUM installation instructions, e.g. as a wireless
sender/receiver (function 3).
Once the wireless universal module has been
configured as per the instructions, it can be added
to the system.
1.
Select Add/Del WAM.
2.
Select the corresponding wireless universal module
(WAM). Up to eight wireless universal modules
can be taught in.
3.
Select, for example, WAM 1.
4.
Trigger the tamper contact on the WAM.
Note
When WAM modules are taught in, the symbol
appears next to the WAM number.
Check the information of the wireless universal
module.
5.
Select WAM Info.

Advertisement

Table of Contents
loading