Abus SECVEST Installer Manual page 88

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Configuration
Siren Delay [min]
Siren time Ext. [min]
88
Time for the delay duration of the siren(s).
The siren delay can be set to a value between 0 and 10 min.
When an alarm has been triggered the alarm panel waits until this time has expired
before it activates the sirens.
Note
The siren delay only goes into effect when the alarm response includes comms.
The siren delay does not go into effect when a comms fault occurs.
The siren delay does not come into effect when "Installer Mode->System-
>Confirmation->Confirmation Mode->DD243 or BS8243" and "Installer Mode-
>System->Confirmation->Siren On ->Unconfirm" are set.
If sounders are assigned to multiple partitions, the alarm panel uses the shortest
siren delay set for the partitions in question.
Time for the duration of the external siren(s) in minutes.
The siren time can be set to a value between 0 and 15 min.
If sounders (or just control devices?) are assigned to multiple partitions, the alarm
panel uses the longest siren time set for the partitions in question.
The time for which the sounders are active can also be extended to the longest
siren delay for that sub-area.