Abus SECVEST Installer Manual page 179

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Fuses
Mains fuse (AC in)
Name
Characteristic
Operating current
Breaking capacity
Operating voltage
Design
Wireless signal transmission
Operating frequency
Modulation
Bandwidth
Transmission power
Sensitivity
Signal-to-noise ratio
Antenna
Range
Special features
RFID proximity keyfob reader
Operating frequency
Special features
Connections
L
N
- DC IN +
13.8 V
Miniature fuse (micro fuse)
removable
T1AL250V
T = slow blow
1 A
L = low
250 V
Glass tube 5x20 mm
868.6625 MHz
In accordance with:
EN 50131-5-3 Grade 2
EN 300 220-1 V.2.1.1
EN 300 220-2 V.2.1.1
EN 300 220-3 V.1.1.1
Frequency band reserved for applications in the security zone.
FM
+/- 10 kHz
Narrow band,
25 kHz channel separation
10 mW
approx. –110dBm
12dB
Integrated duplex antenna technology
Indoors: approximately 30 m
depending on environmental factors
Outdoors: approximately 100 m
Individual identification
Supervision monitoring
Jamming detection
13.56 MHz
In accordance with:
EN 300 330-2
Individual identification
Mains connection
110 V/230 V AC, 50/60 Hz, (85-265 V AC, 50/60 Hz)
L – line, single phase (black or brown)
– protective earth (yellow/green)
N – neutral (blue)
External PSU input
13.8 V DC, external PSU at least 1.7 A
See Power supply section for more details