Commissioning

Initial commissioning/factory reset

Note
The wireless alarm system cannot be accessed
via the web server without running the
installation/start wizard.
Connect your PC to your customer's network.
1.
2.
Switch on the power supply.
3.
Follow the installation/start wizard on the alarm
panel.
4.
Select:
your desired menu language
the desired software version for the alarm panel
your country, for country-specific settings
the current date
the current time
whether switching between daylight
savings/standard time is to be carried out
manually or automatically.
A/C error message for 230 V power supply.
You will then receive error messages in the
event of such faults.
External D/C power supply error message for
13.8 V DC power supply. You will then receive
error messages in the event of such faults.
Battery 2 if it will also be used.
the type of wired zone (e.g. 2-wire FSL
2k2/4k7).
whether access via the web server is/is not
permitted. Set to "permitted" as standard
whether the system should obtain the
IP address automatically or if you wish to
enter the IP address manually
o Automatic DHCP on
o Manual DCHP off, the following menus
appear where you can enter the address:
o IP address
o IP Subnet mask
o Gateway IP address
o Initial IP address of the DNS server
Internal HTTP port
The overview then displays:
o the IP address of the wireless alarm system
o DHCP ON/OFF
o the current software version
o the serial number of the wireless alarm
system
o the part number of the wireless alarm
system
ARC/ESCC reporting, whether reports are to be
sent to monitoring station
the length of the access code, 4 or 6 characters
the installer code (S/W >=1.01.00)
the administrator code (S/W >=1.01.02)
5.
The overview then displays:
the temporary login data for the installer and
administrator.
6.
Make a note of the IP address.
7.
Open the web browser on your PC and enter the
IP address indicated by the alarm panel.
Alternatively you can also use the ABUS IP Installer
to display the alarm panel and automatically access
it. You can download the IP Installer from
www.abus.com.
8.
Connect to the wireless alarm system via the web
browser.
Note
When the alarm panel is first set up, it may take
up to three minutes for the web browser to access
the wireless alarm system as the SSL certificate is
automatically generated during this time.
A window appears with the following message:
SSL certificate will be created, this can take
several minutes.
Network functions are not available during this
time.
Note
This message will display: Network initialisation,
please wait...
9.
Log into the wireless alarm system as an installer.
Commissioning