Configuration
Type
Alarm Abort
Medical Alarm
Nursing emergency call
Tamper Activated
Radio frequency failure
RF Supervision
RF Jamming
RF Low Battery
Battery Fault
66
Explanation
The output is activated when an alarm is interrupted by
the user in the selected partition during the possible time
period. The output is deactivated as soon as the alarm
is confirmed.
This output is activated when a medical emergency call
is triggered.
This output is activated when a social care call is
triggered.
The output is activated when the alarm panel receives
a tamper alarm from one of the following devices:
 Alarm panel (cover or wall tampering)
 Control device (cover or wall tampering)
 Zone with zone type "Tamper"
 All wireless detectors or WAM
 Sirens
The alarm panel deactivates the output as soon as the
cause of tampering has been corrected.
This output is activated as soon as one of the three RF
faults listed below occur:
This may be the following: RF Low Battery,
RF Supervision, RF Jamming. The output is deactivated
only when the fault is reset on the alarm panel.
This output is activated as soon as any wireless zone
reports a monitoring failure (supervision fault).
The output remains activated until all supervision faults
have stopped.
The corresponding output is activated when signal
jamming is detected.
The output remains activated until the signal jamming
is corrected.
The output is activated as soon as a wireless detector
sends a low battery message.
The output remains activated until all detectors no longer
send this message.
The output is activated when the alarm panel identifies
a fault with the backup battery OR a zone with zone type
"Ext PSU Batt Fault" is triggered.
If the alarm is triggered by a zone with "Ext PSU Batt
Fault" the alarm panel only deactivates the output when
the zone itself is reset and the user confirms the fault with
a valid code on the alarm panel.
If the alarm is triggered by a fault with the backup battery,
the output is only deactivated again as soon as the alarm
panel detects a suitable and functioning battery.
Note: check the function of the battery using the test
function available in the menu on the alarm panel.
Can be assigned
to partitions
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No