Configuration
Name/function
Exit Mode,
cont.
80
Explanation
Final Door Set
Use this option to complete internal arming of a partition by closing the last exit
door. This door has a detector with zone type "Final Door". When the door is
closed, the partition is internally armed once the settle time has expired.
Note that the exit time for this option is unlimited, i.e. when the zone is closed
(closed door) the alarm panel waits until this zone is opened and then closed
again before internally arming.
The alarm panel saves the start time of internal arming (and not the internal
arming itself) in the log book.
Do not attempt to use a PIR zone as a "Final Door" for a partition. PIR wireless
detectors has a "lock" time period after each arming, in order to save battery
power. If a partition is armed (or internally armed), a PIR detector may still be
locked. During this time it cannot send signals to complete the arming process.
Instant Set
The partition is internally armed immediately without any acoustic warning tone.
If the partition has been internally armed, an acoustic confirmation sounds.
Note: This option does not comply with BS8243:2010.
Silent Set
The partition is internally armed after the exit time has expired. Under "Exit time"
select the corresponding time. However, no warning tone sounds during this time.
If the partition has been internally armed, an acoustic confirmation sounds.
The alarm panel saves the start time in the log book.
During entry time the acoustic warning tone can be heard.
Note: This option does not comply with BS8243:2010.
Lock Set
The "Lock Set" mode affects both internal arming and disarming of the partition.
For this mode, a detector with zone type "Lock Set" and a detector with zone
type "Final Door" must be assigned at the last exit door. The detector with
zone type "Lock Set" is operated with a lock switch contact on a suitable lock.