Name/function
Unset Comms
Burg
Comms
Rearm
Dynamic Test Call
Telecoms Priority
Static Test Call
Only when "Dynamic Test Call"
is deactivated
SET THE HOUR
For "Static Test Call" only
 Daily
 Weekly
 Monthly
Explanation (checkbox)
Armed
The alarm system transmits all status messages to the ARC, regardless of whether
the system is armed or disarmed.
Deactivated
The alarm system transmits tamper, network failure and other status messages
to the ARC while it is armed. When disarmed, the status messages are not
transmitted to the ARC.
Appears only when the following is set: "System  Confirmation  Confirmation
mode = Basic" and "Communications  Protocol = Fast Format")
Armed
 The alarm system activates channel 3 again as soon as the siren time has
expired. After channel 3 has been reactivated, an event can be transmitted again
if it occurs. The system automatically omits triggered zones in this case.
 Note: if a "Final Door" zone is triggered, channel 3 is activated at the end
of the configured entry/exit time.
Deactivated
Channel 3 remains activated until a user or installer resets the system.
Armed
The dynamic test call is activated.
Deactivated
The dynamic test call is deactivated. The "Static Test Call" dropdown selection
field appears.
Set the order in which the communication methods should be used here.
 Ethernet
1, 2, 3 or No
 PSTN
1, 2, 3 or No
 GSM
1, 2, 3 or No
Note:
The alarm control panel automatically uses the IP-based protocol DC-09 if the
alarm control panel uses Ethernet (LAN) as an outgoing communication path.
In doing so, the data from traditional protocols are packed into IP packages and
transferred.
For details, see the "ARC/ESCC reporting protocols" appendix
Dropdown selection field for:
 Disabled
 Daily
 Weekly
 Monthly
Input field for the time of the daily test call (hh:mm)
Configuration