Abus SECVEST Installer Manual page 181

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Z301A/Z301T, Z302A/Z302T
Resistance ranges specified for idle, alarm and tamper states (in Ohms).
Resistances immediately by the screw terminals.
Recommended cable resistance: must be less than 100 Ohms.
2-wire FSL
2K2/4K7
O/C tampering
8281-∞
Alarm
4081-8280
Idle
1760-4080
S/C tampering
0-1759
Open/alarm/tampering
Closed/idle
Communication
Communication channels
a/b interface
Ethernet
GSM
Communication methods
Web server
ARC/ESCC reporting
Receiver
Protocols
Wired Zones
4-wire CC
2-wire FSL
1K/1K
2401-∞
1401-2400
800-1400
0-799
4-wire CC
1001-∞
0-1000
Interface for analogue telephone connection to the public telephone
network, a private branch exchange or an integrated access device
(IAD)
10/100 LAN
Plug-in module, optional
Quad-band GSM: 850/900/1800/1900 MHz
Web access, app and ABUS server
2 Tel, 2 IP
Analogue
IP
2-wire FSL
2-wire FSL 4K7/4K7
2K2/2K2
5281-∞
11281-∞
3081-5280
6581-11280
1760-3080
3760-6580
0-1759
0-3759
2-wire CC
1001-∞
0-1000
Fast Format, Contact ID, SIA 1, SIA 2, Ex SIA 3, Ex SIA 3
V2, CID in SMS
DC-09 (SIA-IP), with Fast Format, Contact ID, SIA
Protocol
Token
"SCN-S8"
FF
"ADM-CID"
CID
"SIA-DCS"
SIA 1, SIA 2,
SIA 3, Ex SIA 3,
Ex SIA 3 V2
TCP, unencrypted
Note:
For details, see the appendix to the instructions for
installers entitled "ARC (ESCC) reporting protocol
formats"
Appendix
181

Advertisement

Table of Contents
loading

Table of Contents