Role
Wireless control panel Testing of wireless control panels is carried out in the web interface in the same manner
Meaning
as on the alarm panel.
Press the function buttons on the wireless control device one after the other.
Wait 2 to 3 seconds between each button so that the control device can send each
message.
A corresponding letter appears on the display in response:
A = "arm" button (closed lock)
C = "internal arm" button (*)
D= "query status" button (?)
B = "disarm" button (open lock)
On the Web you will also see:
Arm system key
Arm system internally key
Status query
Disarm system key
To test the number buttons, press 4 or 6 numerical buttons (corresponding to the set code
length) and then a function button: Example:
 Press
: 1234?
 Displayed
: 1234D (status query)
Press the dual keys (fire alarm, hold up alarm, medical emergency or social care alarm)
at the same time to test them. On the display:
F = dual keys fire alarm
P = dual keys hold up
M = dual keys medical emergency
H = dual keys social care alarm
On the Web you will also see:
Fire key
Intrusion key
Medical emergency call key
Social Care Key
The lower "*" and "#" button on the control device cannot be tested.