Appendix

S/W upgrade

Important
Saving and restoring the configuration
As part of a comprehensive update, the Secvest wireless alarm system is reset to the factory defaults.
It is therefore essential to save the alarm control panel configuration in advance:
1. "Installer Mode" web server
2. "System"
3. "Backup/restore"
4. "Backup"
After completing the update, the configuration (inc. all component IDs) can be restored:
5. "Installer Mode" web server
6. "System"
7. "Backup/restore"
8. "Load Configuration"
Important
Changes have been made to the following menus as part of S/W 2.00.00
VoIP Dialler Setup
Contacts -> SIP User ID
Outputs -> Type "User defined"
ARC/ESCC reporting -> IP port
Please check these menus after carrying out the configuration and adjust the settings accordingly.
Remote Updates
Preparation:
Adding new "Level 4 user"
Alarm panel
Installer Mode -> System -> Security -> Remote Updates -> Enabled
Or
WBI
Installer Mode -> System -> Security Settings -> Remote Updates -> Enabled (activated, ticked)
If this option is activated, a new Level 4 code must be entered. This is only the case if this Level 4 code
was never programmed to begin with (as delivered or since the last reset to the factory defaults). This Level 4
code has the same number of digits as the Installer code or the User code.
Enter a "New Level 4 code" and "Confirm Level 4 code" (enter the code again to confirm it).
A new user is added automatically. See "User" menu.
Name: "Level4"
Note:
For security reasons, you should change the "Level4" default name of the Level 4 user.
Note:
Further details can be found under the menu explanations in the corresponding instruction manuals.