Configuration
Type
Explanation
Final Door
When the alarm panel is armed, this zone triggers an alarm once the set delay time (entry delay)
has expired. Use this zone type for the magnetic contact on the entrance door, for example.
When exiting the premises, closing this zone can also be used to end the exit delay.
This detector can be used as a "Normal Alarm" when the system is armed internally.
Entry Route
This zone does not trigger an alarm if a "Final Door" zone has previously activated the entry
delay time. An immediate alarm is triggered if no entry delay has previously been activated.
Use this zone type for a motion detector in the entrance area, directed at the entrance door
(which is fitted with a magnetic contact), for example. This detector can be used as a "Final Door"
detector when the system is armed internally. It is possible to exit the configuration menu when
this zone is open.
Technical Alarm A "Technical Alarm" zone triggers an alarm and communication when the system is disarmed.
When the system is armed, only communication is sent; no alarm is triggered. If an alarm is
triggered in this zone when the system is armed, it is displayed on the alarm panel when the
system is disarmed. Use this zone type for flood detectors, for example. The wireless info
module and the wireless indoor siren signal technical alarms with beeps, like the alarm panel.
Key Switch
Teach in a (momentary) key switch on the wireless alarm panel. A change to this zone changes
(Moment.)
the status of the alarm panel from set to unset, or from unset to set (after the delay time has
expired).
Key Switch
A (latched) key switch can be connected to the alarm panel. A change to this zone changes the
(Latched)
status of the alarm panel from set to unset, or from unset to set (after the delay time has expired).
Note that the alarm panel is only operated via the key switch. When the status is not known,
e.g. when the key switch is closed but disabled on the control device at the same time, the
alarm panel may return to the "Set" status.
Key Box
This zone is mainly used in Scandinavia. If this zone is opened, this event is saved in the alarm
panel memory. It can also be transmitted via the telephone dialler at the same time. It does not
trigger an alarm.
If a zone of this type is required, the installer usually connects the alarm wires of this zone (usually
the auxiliary contacts of a door contact) to an external key box and the tamper wires to the tamper
switch of the housing.
If the housing is opened, the wireless alarm panel saves the event and reports it to the alarm
reception centre.
Tamper
This zone is used for tamper monitoring of external devices. Monitoring of this zone is permanently
Activated
enabled. If the alarm panel is disarmed, only the internal siren is triggered. If the alarm panel is
armed, the external siren and strobe are triggered and communication is sent according to the
configuration.
Log only
If a "Log Only" zone is triggered (alarm or tampering), only a log book entry is created and an
output that follows this zone is triggered. The zone can be triggered when the alarm panel is
armed or disarmed.
"Log Only" zones can be assigned to multiple partitions and can have the "Chime" attribute.
Exit Terminate
This zone is used to cancel the exit delay for a partition with the "Exit Terminate" attribute.
This zone type is typically used for key switch (NO). Note: this zone is enabled during the exit time
but disabled when the wireless alarm panel is armed or disarmed. If the "Chime" attribute is
assigned to this zone, the doorbell sounds both when the wireless alarm panel is armed and
disarmed.
Lock Set
This zone is used to cancel the exit delay for a partition with the "Lock Set" attribute. This zone
type is typically used for a switch (NO). Note: this zone is enabled during the exit time and when
the wireless alarm panel is armed. This zone can be assigned to the "Inverted" attribute.
Ext WD Fault
This zone is used to monitor the fault output of external sounders. If a fault output with this zone
type is triggered, "Ext WD Fault" appears on the display. This zone type is not available for wireless
zones.