for the FUAA50000, FUAA50010, FUAA50100 and FUAA50110 Secvest wireless alarm panel systems
Standards with which the alarm panel claims compliance
EN50131-1:2006+A1:2009
EN50131-3:2009
EN50131-5-3:2005+A1:2008
EN50131-6:2008+A1:2014
EN50131-10:2014
EN50136-2:2013
INCERT TO31 2014 edition
Security level: Level 2
Environmental class: Class II
If the alarm panel has been installed correctly, the Secvest will be compliant with EN50131 Grade 2.
The Secvest is compliant with EN50131-1 and EN50130-5 environmental class II.
Power supply is compliant with EN50131-1:2006+A1 2009 Section 9 and EN50131-6 if the alarm panel has been
installed correctly.
The alarm transmission system (integrated SP2 [ATS2] communicator) is compliant with EN50136-1:2012 as an SP2
(ATS2) communicator.
At Grade 2 the integrated SP2 (ATS2) communicator provides a compliant communicator for the Secvest
on the condition that
a) it is installed as specified in the installation instructions
b) the connected PSTN, LAN and GSM work normally
c) the alarm receiving centre has the right equipment.
The FUMO5000X GSM module can be used as a supplementary communicator for Grade 2.
The alarm panel supports options A, B and C for grade 2 as given in Table 10 in EN50131-1:2006+A1:2009.
If the installer selects a non-compliant configuration the compliance label must be removed or corrected.
Third party verification of compliance was carried out by ANPI.
Web browser via the integrated web server or directly on the alarm