Configuration
Tamper Omit
Force Set
110
If the Level 4 code is then used for accessing the alarm control panel,
only the following menu options appear
Level 4 User Name
Level 4 User Code
to allow the user to change the name and code.
See "S/W Upgrade" appendix. You will find details about the S/W upgrade
process there.
If a user omits a zone it may be necessary to also omit the associated tamper
circuit for this zone.
Armed
The tamper contact is also omitted within an omitted zone.
Deactivated
The tamper contact continues to be monitored within an omitted zone.
A user can be permitted to arm the alarm panel using the remote control even
if one or more zones are not working or are open.
Note
If Force Set is enabled, the system is no longer compliant with EN 50131.
Dropdown selection field for:
 Off
 The user cannot force the system to arm with the remote control even
if the corresponding zones have been given attribute "Force Set".
 Confirm
 The user can force the system to arm with the remote control. To do so,
proceed as follows:
1. The user presses the "arm" button on the remote control.
2. The system does not start arming.
3. The user presses the same button on the remote control again to confirm
that the system should arm.
 On
 The user only has to press the corresponding button on the remote control
once to start the arming process.
Note
With the "Confirm" and "On" options, the user is also permitted to arm the system
with the remote control even if it would need to be reset after an alarm.