Repairs and maintenance

The alarm control panel should be checked once a year. During every inspection:
Check the Secvest for visible signs of damage on the housing or the front cover.
Check the condition of the housing-tampering switch and the wall-tampering switch (wall-removal contact)
Check the condition of the backup battery
Check the cabling for visible signs of damage or wear
Check the keypad for visible signs of damage
Test the function of all keys on the keypad
Clean the keypad surface, the display and the housing
o
When cleaning the surface, use a soft, dry cloth.
o
Do not use any water, solvents or cleaning agents.
Check the signal strength and the battery condition of all detectors, keypads, external sirens, indoor sirens,
WAMs, door locks, remotes, hold up pendants, medical pendants and care pendants.
Replace the batteries when recommended by the manufacturer
Test every component.
Carefully clean the lenses on all PIR detectors and cameras using a soft, clean, dry cloth.
Do not use any water, solvents or cleaning agents.
Carry out a walk test on all detectors.
Test all external sounders
Test the communication.
EN50131-7 "Alarm systems – intrusion and hold up alarms – part 7: application rules" must also be taken into
consideration.
It is not necessary to check any calibrations or adjustments.