4
FUNCTIONS
This chapter describes the functions available of the master/intelligent device module.
4.1

Function List

Cyclic transmission
This section describes the functions of the CC-Link system.
: Available, : Not available
Functions
Communication
Communication using
with other
RX, RY
stations
Communication using
RWr, RWw
Mode
Remote net Ver.1 mode
Remote net Ver.2 mode
Link refresh
Cyclic data integrity assurance
Setting of the input data from a data link
faulty station
Output data setting for CPU STOP
Data link setting when CPU is down
Output data setting for CPU error
Data link stop and restart
4 FUNCTIONS
26
4.1 Function List
Description
Communicates I/O data in units of bits between the master station
and other stations.
Communicates I/O data in units of words between the master station
and other stations.
The mode can be selected according to the CC-Link system
configuration.
Automatically transfers data between the link device of the master/
intelligent device module and the device of the CPU module.
Prevents the link refreshed read/write data from being separated
between new and old data.
When
Selects whether remote input (RX) from a station
operating
where a data link error occurs is cleared or held.
as a master
station
When
Selects whether output data (RY/RWw) from the
operating
master station is cleared or held.
as an
intelligent
device
station
When
Selects whether remote output (RY) is refreshed (held
operating
at the value before STOP) or cleared to zero (0) when
as a master
the CPU module is set to STOP.
station
When
Selects whether input data to the master station (RX/
operating
RWr) is refreshed (held at the value before STOP) or
as an
cleared to zero (0) when the CPU module is set to
intelligent
STOP.
device
station
Selects whether data link is stopped or continued when a stop error
occurs in the CPU module.
When
Selects whether remote output (RY) to the slave
operating
station is held or cleared when a stop error occurs in
as a master
the CPU module.
station
When
Selects whether remote input (RX/RWr) to the master
operating
station is held or cleared when a stop error occurs in
as an
the CPU module.
intelligent
device
station
Stops data link during debugging and other operations. (Data
sending from the own station is stopped.) Also, the stopped data link
is restarted.
Availability
Reference
Master
Intelligent
Station
device
station
Page 29
Page 30
Page 35
Page 36
Page 38
Page 41
Page 38
Page 41