Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 155

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

No.
Name
Description
SW0088,
Fuse blown status
Stores a fuse blown error status.
SW0089
of other stations
0: Normal
1: Fuse blown
SW0088
SW0089
The bits turn on by the number of occupied stations.
Reserved stations, station with the end station number, and stations later than
that are excepted.
The use of b8 to b15 of SW0089 is prohibited.
SW008C,
Switch change
Stores whether the setting of switches of other stations during data link has
SW008D
status of other
been changed.
stations
0: No change
1: Changed
SW008C
SW008D
Only the bit corresponding to the start station number turns on.
Reserved stations, station with the end station number, and stations later than
that are excepted.
The use of b8 to b15 of SW008D is prohibited.
SW0090
Line status
Stores the line status.
0: Normal
1: Data link disabled (disconnected)
SW0094,
Transient
Stores whether a transient transmission error has occurred.
SW0095
transmission
0: No transient transmission error
status
1: Transient transmission error
SW0094
SW0095
Only the bit corresponding to the start station number turns on.
Reserved stations, station with the end station number, and stations later than
that are excepted.
The use of b8 to b15 of SW0095 is prohibited.
SW0098,
Station number
Stores whether station numbers are unique when the start station numbers of
SW0099
overlap status
modules are different.
0: Normal
1: Station number in use (start station number only)
SW0098
SW0099
Reserved stations, station with the end station number, and stations later than
that are excepted.
Only the bit corresponding to the start station number turns on. This item is
checked, and the result is stored only upon data link start and the change of a
parameter.
For a slave station with the transmission speed auto-tracking setting, the station
number already used for other stations may not be detected.
The use of b8 to b15 of SW0099 is prohibited.
b15
b14
to
b8
b7
16
15
to
9
8
-
-
-
-
24
1 to 24 in the table indicate station numbers.
b15
b14
to
b8
b7
16
15
to
9
8
-
-
-
-
24
1 to 24 in the table indicate station numbers.
b15
b14
to
b8
b7
16
15
to
9
8
-
-
-
-
24
1 to 24 in the table indicate station numbers.
b15
b14
to
b8
b7
16
15
to
9
8
-
-
-
-
24
1 to 24 in the table indicate station numbers.
Availability
(: Available, : Not available)
Online
Master
Station
to
b2
b1
b0
to
3
2
1
to
19
18
17
to
b2
b1
b0
to
3
2
1
to
19
18
17
to
b2
b1
b0
to
3
2
1
to
19
18
17
to
b2
b1
b0
to
3
2
1
to
19
18
17
Appendix 6 List of Link Special Register (SW) Areas
Offline
Intelligent
device
station
A
APPX
153

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents