Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 151

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

No.
Name
Description
SW0014,
Specification of
Specifies a station that performs an initial processing using the information
SW0015
remote device
registered by the remote device station initialization setting procedure
station to be
registration using an engineering tool.
initialized
0: Initial processing not performed
1: Initial processing performed
SW0014
SW0015
The stations need not be set by the number of occupied stations.
Error invalid stations, reserved stations, station with the end station number, and
stations later than that are excepted.
The use of b8 to b15 of SW0015 is prohibited.
SW0041
Data link restart
Stores whether the data link restart instruction using SB0000 has been normally
result
completed.
0: Normal
Values other than 0: Error code (Page 118 List of Error Codes)
SW0045
Data link stop
Stores whether the data link stop instruction using SB0002 has been normally
result
completed.
0: Normal
Values other than 0: Error code (Page 118 List of Error Codes)
SW0049
Temporary error
Stores whether the temporary error invalid station specification has been
invalid station
normally completed.
specification
0: Normal
result
Values other than 0: Error code (Page 118 List of Error Codes)
SW004B
Temporary error
Stores whether the temporary error invalid station setting has been normally
invalid station
canceled.
specification
0: Normal
cancel result
Values other than 0: Error code (Page 118 List of Error Codes)
SW004D
Line test result
Stores the result of a line test.
0: Normal
Values other than 0: Error code (Page 118 List of Error Codes)
SW0057
Master station
Stores whether a master station duplication error cancel request has been
duplication error
normally completed.
cancel result
0: Normal completion
Values other than 0: Error code (Page 118 List of Error Codes)
SW0058
Detailed LED
Stores the details of the LED display status.
display status
0: Off
1: On
b15b14b13b12b11
• The use of b11 and b12 is prohibited.
• The ERR. LED on the master/intelligent device module turns on when a bit of
either among b4 to b8 or b14 is on.
b15
b14
to
b8
b7
16
15
to
9
8
-
-
-
-
24
1 to 24 in the table indicate station numbers.
b10
b9
b8 b7 b6 b5 b4
b3
b2 b1 b0
0
0
0
0
0
0
LINE (ERROR): A cable is disconnected or the transmission path
has been affected by noise.
TIME (ERROR): Responses cannot be received from any station
due to the cable being disconnected or
the transmission path being affected by noise.
PRM (ERROR): Invalid parameter value
M/S (ERROR): Multiple master stations exist on the same line.
SW (ERROR): Error in switch settings
MST: The station is operating as a master station.
ERR.: Error
RUN: The module is operating normally.
Availability
(: Available, : Not available)
Online
Master
Station
to
b2
b1
b0
to
3
2
1
to
19
18
17
Appendix 6 List of Link Special Register (SW) Areas
Offline
Intelligent
device
station
A
APPX
149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents