Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 147

Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

No.
Name
SB000D
Remote device station
initialization procedure
registration instruction
SB0020
Module status
SB0040
Data link restart
acceptance
SB0041
Data link restart
completion
SB0044
Data link stop
acceptance
SB0045
Data link stop
completion
SB0048
Temporary error invalid
acceptance status
SB0049
Temporary error invalid
completion status
SB004A
Temporary error invalid
cancel acceptance
status
SB004B
Temporary error invalid
cancel completion
status
SB004C
Line test acceptance
status
SB004D
Line test completion
status
SB0050
Offline test status
SB0057
Master station
duplication error
cancel acceptance
SB0058
Master station
duplication error
cancel completion
SB005E
Execution status of
remote device station
initialization procedure
Description
Performs an initial processing using the information registered by the
remote device station initialization setting procedure registration using an
engineering tool.
While SB000D is on, the remote I/O and remote registers are stopped to
be refreshed.
Off: Not instructed
On: Instructed
Stores the communication status between the master/intelligent device
module and CPU module.
Off: Normal
On: Error
Stores the data link restart instruction has been accepted.
Off: Not accepted
On: Accepted
Stores the data link restart instruction has been completed.
Off: Not completed
On: Started
Stores the data link stop instruction has been accepted.
Off: Not accepted
On: Accepted
Stores the data link stop instruction has been completed.
Off: Not completed
On: Stopped
Stores the remote station temporary error invalid instruction has been
accepted.
Off: Not executed
On: Accepted
Stores the remote station temporary error invalid instruction has been
completed.
Off: Not executed
On: A temporary error invalid station determined
Stores the remote station temporary error invalid cancel instruction has
been accepted.
Off: Not executed
On: Accepted
Stores the remote station temporary error invalid cancel instruction has
been completed.
Off: Not executed
On: Temporary error invalid station setting canceled
Stores a line test request has been accepted.
Off: Not executed
On: Accepted
Stores a line test has been completed.
Off: Not executed
On: Completed
Stores an offline test is being executed.
Off: Not executed
On: Test in progress
Stores a master station duplication error cancel request has been
accepted.
Off: Not accepted
On: Accepted
Stores a master station duplication error cancel request has been
completed.
Off: Not completed
On: Completed
Stores the initialization procedure is being performed.
Off: Not executed
On: In process
Availability
(: Available, : Not available)
Online
Master
Intelligent
Station
device
station
Appendix 5 List of Link Special Relay (SB) Areas
Offline
A
APPX
145

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents