Transient transmission
: Available, : Not available
Functions
Communications in the same system
RAS
: Available, : Not available
Functions
Slave station cutoff function
Automatic return function
Diagnostics
: Available, : Not available
Functions
Line test
Check of transmission speed setting
CC-Link Diagnostics
Hardware test
Own station/other station monitor
Status logging
Creating a check sheet
Description
Performs the transient transmission to other stations with the
engineering tool.
Description
Disconnects only the slave station where an error occurs from the
system, and continues the data link with the stations that are operating
normally.
Using this function prevents the entire system from going down due to
failure of one slave station.
(No module parameter setting is required.)
Automatically returns the station disconnected from the system due to a
data link error to the system when it recovers and restarts data link.
Since processing for return is unnecessary, it is possible to shorten the
time to recover from an error.
Description
Checks whether a Ver.1.10-compatible CC-Link dedicated cable is
properly connected and data link can be performed with slave stations.
Checks whether the transmission speed setting of a slave station is the
same as that of the master station. The station number of the slave
station having a different transmission speed setting can be also
checked; therefore, corrective action upon a transmission error can be
easily taken.
Checks the status of CC-Link system using the engineering tool. The
error locations, error causes, and corrective actions can be checked in
the engineering tool.
Checks the hardware in the master/intelligent device module.
Checks the data link status, etc. of the CC-Link system with the
engineering tool.
Data link status of all stations is logged.
A check sheet, which is useful for performing troubleshooting, is created
through a wizard and with reference to the Open Field Network CC-Link
Troubleshooting Guide.
Availability
Reference
Master
Intelligent
Station
device
station
Page 45
Availability
Reference
Master
Intelligent
Station
device
station
Page 71
Availability
Reference
Master
Intelligent
Station
device
station
Page 104
Page 106
Page 99
Page 110
Page 103
Page 107
Page 108