Link refresh settings

Set the link refresh range between the link device of master/intelligent device module and the device of CPU module.
Setting method
The procedure for the link refresh settings is shown below.
1.
Set the required items.
2.
Click the [Apply] button to finish the link refresh settings.
Setting items
Item
Description
Device Assignment
Right-click in the setting window and select a link device assignment method
Method
from the "Device Assignment Method" menu.
• Start/End: Enter the start and end numbers of link devices.
• Points/Start: Enter the points and start numbers of link devices.
Link Side
Set the link refresh ranges of SB and SW. One range can be set for each SB
and SW. (Page 35 Link refresh)
Ex.
CPU Side
0000H
Device
Device
name
name
(SB)
(SB)
01FFH
0000H
Device
Device
name
name
(SW)
(SW)
01FFH
FX5-CCL-MS
Setting range
• Start/End
• Points/Start
(Default: Start/End)
Device Name
• SB
• SW
Points
• SB: 16 to 512 (Set it in increments of 16 points.)
• SW: 1 to 512
(Default: Blank)
Start
• SB: 00000H to 001F0H (Set a multiple of 16
including 0.)
0000H
• SW: 00000H to 001FFH
(Default: Blank)
01FFH
End
0000H
• SB: 0000FH to 001FFH (Set a multiple of 16 - 1.)
• SW: 00000H to 001FFH
01FFH
(Default: Blank)
Target
• Device
(Default: Blank)
Device Name
• Specified device (when link side is fixed to SB):
SB, M, L, B, D, W, R
CPU module
(Default: Blank)
• Specified device (when link side is fixed to SW):
SW, M, L, B, D, W, R
(Default: Blank)
Points, Start, End
• Range of the device in the CPU module
7 PARAMETER SETTINGS
7.3 Basic Settings
7
65