Link refresh settings
Set the link refresh range between the link device of master/intelligent device module and the device of CPU module.
Setting method
The procedure for the link refresh settings is shown below.
1.
Set the required items.
2.
Click the [Apply] button to finish the link refresh settings.
Setting items
Item
Description
Device Assignment
Right-click in the setting window and select a link device assignment method
Method
from the "Device Assignment Method" menu.
• Start/End: Enter the start and end numbers of link devices.
• Points/Start: Enter the points and start numbers of link devices.
Link Side
Set the link refresh ranges of SB and SW. One range can be set for each SB
and SW. (Page 35 Link refresh)
Ex.
CPU Side
0000H
Device
Device
name
name
(SB)
(SB)
01FFH
0000H
Device
Device
name
name
(SW)
(SW)
01FFH
FX5-CCL-MS
Setting range
• Start/End
• Points/Start
(Default: Start/End)
Device Name
• SB
• SW
Points
• SB: 16 to 512 (Set it in increments of 16 points.)
• SW: 1 to 512
(Default: Blank)
Start
• SB: 00000H to 001F0H (Set a multiple of 16
including 0.)
0000H
• SW: 00000H to 001FFH
(Default: Blank)
01FFH
End
0000H
• SB: 0000FH to 001FFH (Set a multiple of 16 - 1.)
• SW: 00000H to 001FFH
01FFH
(Default: Blank)
Target
• Device
(Default: Blank)
Device Name
• Specified device (when link side is fixed to SB):
SB, M, L, B, D, W, R
CPU module
(Default: Blank)
• Specified device (when link side is fixed to SW):
SW, M, L, B, D, W, R
(Default: Blank)
Points, Start, End
• Range of the device in the CPU module
7 PARAMETER SETTINGS
7.3 Basic Settings